Wilkerson Instrument Co. Homepage A World of Signal Conditioning & Process Control Instrumentation Products


Model DCT
Digitally Compensated
Pressure Transmitter

FEATURES

bullet Digitally Compensated
bullet Multiple Pressure Port Options
Ease of installation and attachment and no adapters required.
bullet

Numerous Weatherproof Electrical Connection Options
Quick hook-up and remote applications.

bullet

Stainless Steel Construction and Wetted Materials
Resists the corrosive effects of caustic medias or washdowns and compatible with a variety of media.

bullet

0.25% Accuracy
Offers superior accuracy to competitive models and can be used on critical applications.

bullet

Factory Calibrated for Pressure and Temperature
No need for field calibration. Plug and play reliability.

bullet

Wide Pressure Ranges and Types (PSIG, PSIA, Compound)
Can be used in a variety of applications. PSIA and compound units can be used for vacuum to absolute or atmospheric pressures.

bullet

Numerous Electrical Outputs
Can be used with standard process equipment, conventional receivers, and compatible with microprocessors.

bullet

Low Cost
For use by OEMs.

bullet

Rugged, Compact Design
Easy to package or install.

bullet

RFI/EMI Protection
For use in high noise environments.

bullet

Reverse Polarity Protection
Installation safety and not damaged by reverse wiring.

bullet

Custom Designs Available
Adaptable to special needs.

DESCRIPTION

The Model DCT Pressure Transducer is designed for general industrial and commercial requirements offering excellent performance over a wide range of applications. This new model is based on proven micro-machined silicon technology providing high reliability, long-term stability, and low cost relative to competing technologies. 

This product is offered in a variety of mounting and electrical output options, stainless steel or brass construction, and numerous pressure ranges. It is fully digitally compensated for the effects of pressure and temperature change and calibrated to produce industry standard electrical outputs. The DCT accepts both unregulated and regulated excitation voltages and provides output signals such as 1 to 5 VDC, 1 to 6 VDC, 4 to 20mA, 0.5 to 4.5 VDC ratiometric, or a 0 to 100mV output. The DCT Transducer is offered in pressure ranges from 1 psi up to and including 500 psi, and eventually will be offered in ranges as high as 5,000 psi.

The Model DCT is extremely accurate, below 0.25% span over pressure and below 0.50% over a wide compensated temperature range if required (<1.0% standard). The design incorporates a stainless steel isolation diaphragm and 316 stainless steel construction for use with most media types.

The DCT offers premium performance and versatility of use for many applications, both for the general industrial end user and original equipment manufacturers (OEM). It combines precision along with the durability to operate under difficult environmental conditions.

SPECIFICATIONS

Pressure Range: 
Vacuum to 500 psig

Reference Accuracy (includes repeatability, hysteresis, non-linearity—BFSL)
±0.2% full scale TYP, ±0.3% full scale maximum
(consult factory for ranges below 15 psi)

Total Error Band (includes temperature effects and null and span set points): 
±1% full scale

1 Yr. Stability: 
<0.25% full scale

Burst Pressure: 
3x full scale or 750 psig, whichever is less; process media containment up to 2000 psi for stainless steel option

 

Operating Temperature: 
-40 C to 80 C

Process Temperature: 
-40 C to 125 C

Compensated Temperature: 
-25 C to 75 C

Vibration: 
10G, 55 to 2000 Hz

Shock: 
30G

EMC: 
Rated 3 V/m (requires "PE" option)

Process Wetted Material: 
316L stainless steel

Electronics Housing Material
Aluminum or brass for DIN 43-650-C connection

Process Connection: 
7/16-20 SAE, 1/8 NPT, 1/4 NPT

Electrical Connection: 
Cable, DIN, Packard

Outputs
1 to 5
VDC
1 to 6
VDC
0.5 to 4.5
VDC
4 to 20
mA
Input Supply Voltage
9 to 30
VDC
 9 to 30
VDC
5 VDC ±5%
ratiometric
11 to 30
VDC
Load Limitation
50K Ohm
min.
50K Ohm
min.
1M Ohm
min.
900 Ohm
max.

ORDERING INFORMATION

Model

DCT
Pressure Type G = Gauge
V = Vacuum (Use pressure code 0015)
C = Compound (-14.7 psi to full scale)
Pressure Range 0006 = 0 to 6 psi
0015
= 0 to 15 psi
0030 = 0 to 30 psi
0060 = 0 to 60 psi
0100 = 0 to 100 psi
0150 = 0 to 150 psi
0200 = 0 to 200 psi
0300 = 0 to 300 psi
0500 = 0 to 500 psi
Input / Output B = 12 to 30 Vdc / 4 to 20 mADC
C = 9 to 30 Vdc / 1 to 6 Vdc
D = 9 to 30 Vdc / 1 to 5 Vdc
R = 4.75 to 5.25 Vdc / 0.5 to 4.5 Vdc Ratiomatic
Electrical Connection Option PT = 18 inches long, 24 AWG cable
PE = 18 inches long, 24 AWG cable, EMI version
PK = Packard (4 PIN #12162189)
DA = DIN 43 650-A
DC = DIN 43 650-C (industrial type)
Pressure Connection Type 01 = 1/8 Inch NPT
02 = 1/4 Inch NPT
03 = 7/16-20 SAE
Pressure Connection  Material 1 = 316L Stainless Steel
2 = Brass