Wilkerson Instrument Co. Homepage A World of Signal Conditioning & Process Control Instrumentation Products


 

LA7N SERIES
COUNTER (LCD INDICATOR)

FEATURES

bulletNO External Power, Power by Internal Battery
bulletAvailable AC/DC Voltage
NO voltage input types
bulletImproved Circuit Against Noise
bulletScrew Terminal Connections
bulletLCD Indicator
bullet1/32 DIN

SPECIFICATIONS

Series

LA7N

Digit

7 Digit

Model Total Indicator LA7N-1 LA7N-2 LA7N-3 LA7N-4 LA7N-1R LA7N-2R LA7N-3R LA7N-4R LA7N-F LA7N-FR
Operating Mode

UP Mode Only

Power Supply

3 Vdc No External Power (Built In Battery)

Indicating

LCD Zero Blanking Method (Display Size: H 7mm x W 3mm)

Counting Speed 1cps 30cps 1Kcps 7Kcps 1cps 30cps 1Kcps 7Kcps 20cps
Reset System Manual

Non

Have

Non Have
External

Contact Capacity: max. 10 ua

Counting Input

Non Voltage Input:

Impedance at short circuit: Max 10KOhms
Impedance at open circuit: Min 500K Ohms

Free Voltage Input
"H" Level
  24 to 240Vac
  6 to 240 Vdc
"L" Level
  0 to 1.5 Vac
  0 to 2 Vdc
Reset Input

Non Voltage Input:

Impedance at short circuit: Max 10K Ohms
Impedance at open circuit: Min 500K Ohms

Insulation Resistance

100 Meg Ohm Min (at 500 Vdc)

Dielectric Strength 1000Vac 50/60Hz for 1 minute between current carrying terminal
and exposed non-current carrying metal parts
Vibration Mechanical Durability: 10 to 55Hz; 0.75mm double amplitude
Malfunction Durability: 10 to 55Hz; 0.3mm double amplitude
Shock Mechanical Durability: 300m/s2  (approx. 30G)
Malfunction Durability: 100m/s2  (approx. 10G)
Ambient Temperature Operating: -10 to 55 deg C (at non-freezing status)
Storage: -25 to 65 deg C (at non-freezing status)
Battery Life Cycle About 7 Years at 25 deg C
Weight About 2 Ounces (55 grams)

ORDERING INFORMATION