SPECIFICATIONS
INPUT
4-20 mA @ 24 VDC Maximum
DISPLAY
Sharp, 1.0" (25.4 mm) high LCD, ±1999
CALIBRATION
2 Step; non-interacting zero and span
CALIBRATION RANGE
4 mA input: -1000 to +1000; 20 mA between 20 to 2000 counts >4 mA display
MAXIMUM VOLTAGE DROP
1 VDC @ 20 mA
ACCURACY
±0.1% of span, ±1 count
CONNECTIONS
Screw terminal block
OPERATING TEMPERATURE RANGE
-40 to 80°C
APPROVAL
The PD687-EX has been FM and CSA certified as explosion-proof for Class I, Division 1, Groups C and D; dust-ignition proof for Class II, Division 1, Groups E, F, and G; and Class III hazardous (classified) locations. LCIE
(CENELEC) certified as flameproof, EEx d IIB & H2 T6.
ENCLOSURE
Cast aluminum, NEMA 4, 7 and 9, suitable for location in Class I, Division 1, Groups C and D; Class II, Division 1, Groups E, F, and G; Class III hazardous locations. Conduit hole: 3/4.
NPT; user may mount the Display so conduit hole is oriented in any position.
WARRANTY
1 year parts and labor.
EXTENDED WARRANTY
May be extended an additional 12 months by returning the Product Registration Form within 2 months from date of purchase.