PD752
NEMA 4X, 1/8 DIN
TEMPERATURE METER

FEATURES

bullet120 Ohm Nickel RTD
bulletRTD Displayed to 1° or 0.1°
bulletDisplay F° or C°
bulletNo Calibration Necessary
bulletType 4X, NEMA 4X Front Panel
bullet4 Visual Alarm Points with Front Panel LED Status Indication
bullet2 or 4 Relay Options
bullet4-20 mA Output Option
bullet2 or 4 Relays + 4-20 mA Output Option

SPECIFICATIONS

Except where noted all specifications apply to operation at +25°C.

INPUTS
120 Ohm Nickel RTD

DISPLAY
Bright, large, 0.56" (14.2mm) high efficiency red, 4½ digits. F or C may be switched on to indicate Fahrenheit or Celsius.

HOLD READING
Connect switch to ACK/HLD and COM terminals, also connect jumper pins on rear.

ACCURACY
Pre-Calibrated Ranges
Input  Range Accuracy
120 Ohm CU NI RTD -112° to 608°F
-80° to 320°C
±0.2°F
±0.1°C

LOCKOUT
Jumper JP2 at rear of instrument restricts modification of calibration values.

INPUT IMPEDANCE
Greater than 100 kilohms

POWER
AC power: 115 VAC ± 10%, 50/60 Hz, 10VA
230 VAC ± 10%, 50/60 Hz, 10VA
DC power: 18-36 VDC, 6 watts max

ISOLATION
AC power: 1500 VAC; DC power: 500 VDC

NORMAL MODE REJECTION
64 dB at 50/60 Hz

ENVIRONMENTAL
Operational Ambient Temperature Range: 0 to +60¡C
Storage temperature range: -40 to +85¡C
Relative humidity: 0 to 90% non-condensing

ENCLOSURE
1/8 DIN, high impact plastic, UL 94V-0

FRONT PANEL
Type 4X, NEMA 4X, panel gasket provided

CONNECTIONS
Removable screw terminal block

ALARM POINTS
4, any combination of high or low alarms

ALARM STATUS INDICATION
Front panel LED

ALARM DEADBAND
0-100% of full scale, user selectable

UL FILE NUMBER
E160849; 508 Industrial Control Equipment (AC Powered Units Only)

WARRANTY
1 year parts and labor

EXTENDED WARRANTY
Warranty may be extended an additional 12 months by returning the Product Registration Form within 2 months from date of purchase.


OPTIONS 

Relays

RATING
2 or 4 SPDT (form C); rated 2 Amp @ 30 VDC or 2 Amp @ 250 VAC resistive load;
1/14 HP @ 125 / 250 VAC for inductive loads.

RESET
User select

  1. Automatically when the input passes the reset point.
  2. Automatically + manually (via user supplied switch or front panel ACK button). Manual reset resets all manually resetable relays.

FAIL-SAFE OPERATION
The relay coils are energized in the non-alarm condition. In the case of a power failure, the relays will go to the alarm state. Fail-safe operation by removing jumper J2 located on the Options PCB.

AUTO INITIALIZATION
When power is applied to the meter, the relays will always reflect the state of the input to the meter.

DEADBAND
0-100%, user selectable


ISOLATED 4-20 mA TRANSMITTER OUTPUT

CALIBRATION RANGE
Anywhere in range of meter

OUTPUT LOOP RESISTANCE
Power Supply Min. Loop Resistance Max. Loop Resistance
24 VDC 10 ohms 600 ohms
35 VDC (external) 600 ohms 1000 ohms

ACCURACY
± 0.1% F.S., ± .004 mA.

ISOLATION
500 VDC or peak AC, input-to-output or input/output-to-power line.

EXTERNAL LOOP POWER SUPPLY
35 V max.

ORDERING INFORMATION

115 VAC Model 230 VAC Model 24 VDC Model Description Option Card*
PD752-3-N PD752-4-N PD752-2-N No Options  
PD752-3-14 PD752-4-14 PD752-2-14 2 Relays PD174
PD752-3-15 PD752-4-15 PD752-2-15 4-20 mA Output PD175
PD752-3-16 PD752-4-16 PD752-2-16 2 Relays + 4-20 mA Output PD176
PD752-3-17 PD752-4-17 PD752-2-17 4 Relays PD177
PD752-3-18 PD752-4-18 PD752-2-18 4 Relays + 4-20 mA Output PD178