H Series
Variable Frequency
Drive
FEATURES
| Voltage Ratings: |
200-230 VAC, 3 phase
380-460 VAC, 3 phase
| 50 hp to 350 hp | |
| Inverter Type: PWM with IGBT | |
| Control Method: Volts / Hertz with Space Vector Technology | |
| Programmable V/F pattern (Custom curves) | |
| Auto and manual selectable torque boost | |
| Auto energy saving | |
| Multiple stall prevention modes | |
| Built-in PI control | |
| Slip compensation for optimal performance | |
| State of art window based drive software | |
| On board diagnostics | |
| 7 multiple programmable speeds | |
| Adjustable carrier frequency up to 15 kHz | |
| Restart from instantaneous power failure | |
| Stall prevention | |
| 6 programmable multifunction input terminals and 4 output terminals | |
| 2 & 3 wire operation | |
| Speed search | |
| Removable Keypad (Able to read & write parameter for drive cloning) | |
| Programmable auto restart after and during trip | |
| Restart from instantaneous power failure | |
| CE UL cUL ISO9001 |
DESCRIPTION
The H Series is designed for high starting torque applications with IGBT module, Space Vector PWM control algorithm and 32-bit DSP (Digital Single Processor).
Built in PI control enables cost-effective speed regulation of fan and pumps by precise flow, pressure and temperature control. The optimized current and torque control by space vector PWM algorithm and 32-bit DSP enhance power factor by exact torque calculation.
The H Series adapts Space Vector PWM Control algorithm, which allows low THD (Total Harmonic Distortion) and low torque, & current ripples, thereby improves output voltage utility, prevents motor & inverter overheats and enhances power factor of motor.
The H Series has a user-friendly interface and versatile protection functions that make it enable to maximize its capability and to operate motors without trips.
SPECIFICATIONS
460V Class (40 - 125HP)
|
Model Number |
050 | 060 | 075 | 100 |
125 |
|
|
Applicable Motor |
Constant Torque (HP) |
40 | 50 | 60 | 75 |
100 |
|
Constant Torque (kW) |
30 | 37 | 45 | 55 |
75 |
|
|
Variable Torque (HP) |
50 | 60 | 75 | 100 | 125 | |
|
Variable Torque (kW) |
37 | 45 | 55 | 75 | 90 | |
|
Output Ratings |
Constant Torque (FLA) |
61 | 75 | 91 | 110 |
152 |
|
Variable Torque (FLA) |
52 | 62 | 74 | 80 | 160 | |
|
Input Ratings |
Input Voltage |
3 Phase, 380 to 460 V (± 10%) |
||||
|
Input Frequency |
50 to 60 Hz (± 5%) |
|||||
|
Weight (lbs) |
99 |
99 | 139 | 139 |
150 |
|
460V Class (125 - 300HP)
|
Model Number |
150 |
200 |
250 |
300 |
350 | |
|
Applicable Motor |
Constant Torque (HP) |
125 |
150 |
175 |
215 |
300 |
|
Constant Torque (kW) |
90 |
110 |
132 |
160 |
220 | |
|
Variable Torque (HP) |
150 | 200 | 250 | 300 | 350 | |
|
Variable Torque (kW) |
110 | 132 | 160 | 185 | 280 | |
|
Output Ratings |
Constant Torque (FLA) |
183 |
223 |
264 |
325 |
432 |
|
Variable Torque (FLA) |
228 | 264 | 330 | 361 | 477 | |
|
Input Ratings |
Input Voltage |
3 Phase, 380 to 460 V (± 10%) |
||||
|
Input Frequency |
50 to 60 Hz (± 5%) |
|||||
|
Weight (lbs) |
216 |
2165 |
269 |
269 |
386 | |
All Models:
|
Output Ratings |
Max. Frequency |
0.5 to 400 Hz |
|
Output Voltage |
3 Phase, 0 to Input Voltage |
|
|
Control |
Control Method |
Space Vector PWM |
|
Frequency Resolution |
0.01 Hz |
|
|
Frequency Accuracy |
0.01% of Maximum Frequency
(Digital Setting) |
|
|
V/F Ratio |
Linear, Non-linear, User Programmable |
|
|
Braking Torque(w/o DB) |
About 20% |
|
|
Overload Capacity CT |
150% for 1 minute |
|
|
Overload Capacity VT |
120% for 1 minute |
|
|
Torque Boost |
0 to 20% programmable |
|
|
Operating |
Operation Method |
Key-pad Control |
|
Frequency Setting |
Analog: 0 to 10 V / 4 to 20 mA |
|
|
Acceleration / |
0.1 to 6,000 sec |
|
|
Multi-Step |
8 Preset Operation Speed (Programmable) |
|
|
Programmable I/O |
Programmable Input |
6 Programmable Inputs |
|
Programmable Output |
5 Programmable Outputs |
|
|
Protective |
Inverter Trip |
Overvoltage, Undervolatage, Overcurrent, Fuse Open, Ground Fault, Inverter Overheat, Motor Overheat, Main CPU Error. |
|
Stall Prevention |
Over-current Prevention |
|
|
Instant Power Failure |
Below 15 msec: continuous
operation |
|
|
Operating |
Ambient Temperature |
14 °F to 104 °F (-10 °C to 40 °C) |
|
Humidity |
Below 90% Relative Humidity (Non Condensing) |
|
|
Altitude |
Less than 3,300ft (1,000m) without de-rating |
|
|
Cooling System |
Forced Air Cooling |
ORDERING INFORMATION
|
460V |
||||
| Model | Motor Ratings | |||
|
Constant Torque Application (1) |
Variable Torque Application (1) |
|||
|
HP |
kW |
HP |
kW |
|
| CI-050-H4 |
40 |
30 |
50 / 60 |
30 |
| CI-060-H4 |
50 |
37 |
60 / 75 |
37 |
| CI-075-H4 |
60 |
45 |
75 |
45 |
| CI-100-H4 |
75 |
55 |
100 |
55 |
| CI-125-H4 |
100 |
75 |
125 |
75 |
| CI-150-H4 |
125 |
90 |
150 |
90 |
| CI-200-H4 |
150 |
110 |
200 |
110 |
| CI-250-H4 |
175 |
132 |
250 |
132 |
| CI-300-H4 |
225 |
160 |
300 |
160 |
| CI-350-H4 |
300 |
220 |
350 |
220 |