PD691
NEMA 4X
4½ DIGIT LED
STRAIN GAUGE INPUT
PROCESS INDICATOR

FEATURES

bullet 0-30 mV, 0-200 mV, ±15 mV, ±100 mV Field Selectable Inputs
bullet Field Selectable 5, 10 or 24 VDC Excitation Power Supply
bullet Easy Single Button Scaling with Lockout Feature
bullet Peak Hold Feature
bullet Capture or Programmable Tare Feature
bullet 4 ½ Digit + Extra Zero Display
bullet Steady, Accurate Display to 199,990
bullet Type 4X, NEMA 4X Front Panel
bullet 11 Point Linearization
bullet 4 Visual Alarm Points with Front Panel LED Status Indication
bullet 2 or 4 Relays + 4-20 mA Output Options
bullet Green Display Available

SPECIFICATIONS

Except where noted all specifications apply to operation at +25ºC

INPUTS
Field selectable: 0-30 mV, 0-200 mV, ±15 mV, ±100 mV

RATIOMETRIC
Deviation less than 0.1% of full scale, ± 1 count, with ±10% variation in excitation voltage.

DISPLAY
Bright, large, 0.56" (14.2 mm) high efficiency red or green LED. 4½ digits + extra zero may be switched on to display ±19,999(0). Leading zeros blanked.

CALIBRATION RANGE
0 mV input may be set anywhere in range of the meter. 200 mV may be set anywhere above or below 0 mV input.

ISOLATED POWER SUPPLY
Selectable 5 VDC or 10 VDC ± 5% @ 50 mA or 24 VDC ± 5% @ 20 mA.     
Use to power either strain gauge or 4-20 mA output signal, (maximum load resistance of 1200 W).

PEAK HOLD
Captures peak reading and displays it via the front panel ENTER button.

PEAK HOLD INDICATION
Front panel LED

TARE
Captures/sets current display to zero via front panel TARE button.
Programmable tare: automatically sets tare to a preset value.

TARE INDICATION
Front panel LED

ACCURACY
0.05% of full scale, ± 1 count

NON-VOLATILE MEMORY
All programming values are stored in non-volatile memory for ten years if power is lost.

ZERO STABILITY
0.5 µV/°C

SPAN STABILITY
0.005% of full scale /°C

LOCKOUT
Switch 8 at rear of instrument restricts modification of programmed values.

INPUT IMPEDANCE
20 kilohms

POWER
115 VAC or 230 VAC ±10%, 50/60 Hz, 10 VA

ISOLATION
AC power: 1500 VAC
DC power: 500 VDC

ENVIRONMENTAL:
Operational Ambient Temperature Range: 0 to 60°C
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing

ALARM POINTS
4, any combination of high or low alarms

ALARM STATUS INDICATION
Front panel LED

ALARM DEADBAND
0-100% of full scale, user selectable

RELAYS

RATING
2 or 4 relays; SPDT (form C); rated 2 Amp @ 30 VDC or 2 Amp @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for NC contacts and 1/10 HP @ 125/250 VAC for NO contacts, inductive load.

RESET

  1. User selectable
  2. Automatically when the input passes the reset point.
  3. Automatically + manually (via user supplied switch). Manual reset resets all manually resetable relays, (that have been tripped).

FAIL-SAFE OPERATION
The relay coils are energized in the non-alarm condition. In the case of a power failure, the relays will go to the alarm state. May be disabled with internal jumper.

AUTO INITIALIZATION
When power is applied to the meter, the relays will always reflect the state of the input to the meter.

DEADBAND
0-100%, user selectable

ISOLATED 4-20 mA TRANSMITTER OUTPUT

CALIBRATION RANGE
The transmitter output can be calibrated so that a 4 mA output is produced for any number displayed on the meter. The 20 mA output may correspond to any number displayed on the meter that is at least 501 counts greater or smaller than the 4 mA output display. (Ex. 4 mA = 0, 20 mA = 501) If the span between 4 and 20 mA is less than 501 counts, an error message will appear.

OUTPUT LOOP RESISTANCE
Power Supply Min. Loop Resistance Max. Loop Resistance
24 VDC 10 ohms 600 ohms
35 VDC (external) 600 ohms 1000 ohms

ACCURACY
± 0.1% FS, ± .004 mA

ISOLATION
500 VDC or peak AC, input-to-output or input/output-to-power line

EXTERNAL LOOP POWER SUPPLY
35 V maximum

ENCLOSURE
1/8 DIN, high impact plastic, UL 94V-0

FRONT PANEL
Type 4X, NEMA 4X, panel gasket provided

CONNECTIONS
Removable screw terminal block, accepts 22 to 12 AWG

UL FILE NUMBER
E160849; 508 Industrial Control Equipment

ORDERING INFORMATION

115/230 VAC
MODEL
24 VDC
MODEL
DESCRIPTION OPTION CARDS *
PD691-3-N PD691-4-N No Options No Options
PD691-3-14 PD693-4-14 2 Relays PD174
PD691-3-15 PD693-4-15 4-20 mA Output PD175
PD691-3-16 PD693-4-16 2 Relays + 4-20 mA Output PD176
PD691-3-17 PD693-4-17 4 Relays PD177
PD691-3-18 PD693-4-18 4 Relays + 4-20 mA Output PD178

Add (-G) to part number to call out meters with green display.

Example: PD691-3G-14

*Part numbers for Option Cards when purchased Separately.